COBALT 60
Main application: Level gauges - Gamma Radiography
Description:
Simple or double stainless steel capsule containing
Co-60.
Specifications:
• Source: high nickel-plated cobalt
• Capsule: welded stainless steel (AISI 31 6L)
• Half-life: 5.27 years
Delivery time:
• Level gauges: 3 weeks
• Gammagraphy: on request
Source disposal: for each source purchased, Agiris will
provide disposal of one source as per the price list
Radiation energies in MeV:
Gamma Beta
1.17(100%) 0.138(100%)
1.33(100%) 1.491 (0.1%)
Air Kerma Rate at 1 metre: 11.4 mGy/h for 37 GBq
(exposure rate at 1 metre: 1 .3 RIh for 1 Ci)
دريافت اطلاعات كامل :
========================================================
IRIDIUM 192
Gamma Track Ir-192 pellets ere unique -with a wide range of pellets to match a maximum number of sizes and activities.
Optimal sharpness
The iridium is centered in the pellets, and their thickness is selected for the best geometry. The pellets do not deform -due to reactor irradiation. That’s why Gamma Track sources provide optimal image sharpness.
Tailored to customer needs
using a combination of pellets, the source can be manufactured with an active diameter ranging from 0.5 to 4mm! and a height ranging from 0.33 to4mm. using just one pellet, or combining several of them, enables the versatility to make customers’ sources to the exact dimensions and activities that they require tor their specific applications.
Main application: Gamma Radiography
Description:
Simple or double stainless steel capsule containing lr-92 pellets
Specifications:
.• Source: high purity iridium >99.9%
• Capsule: welded stainless steel (41Sf 31 6L) .. Half-life: 73.831 days
Delivery time:
3 to 7 days (except 4 mm, which is available only on request with the delivery time depending on reactor schedule)
Source disposal: For each source purchased, A giris will provide tree disposal of one source.
دريافت اطلاعات كامل :
========================================================
SELENIUM 75
Main application: Gamma Radiography
Description:
Se-75 inside primary vanadium capsule
Specifications:
• Source: Se-75
• Capsule: double capsule
(inner vanadium capsule - outer stainless steel capsule)
• Half-life: 119.8 days
Delivery time:
from 1 to 2 weeks for 3 x 3 mm and 2.5 x 2.5 mm; from 3 to 4 months for other dimensions, depending on reactor schedule.
Source disposal:
Free of charge but mandatory
<!--[if !supportLineBreakNewLine]-->
<!--[endif]-->
Radiation energies in MeV
Gamma
136.002 (59.4%)
121 .119 (17.43%)
264.656 (59.5%)
279.538 (25.3%)
others
Air Kerma Rate at 1 metre: 1 .95 mGy/h for 37 GBq (exposure rate at 1 metre: 0.224 RJh for 1 Ci)
دريافت اطلاعات كامل :